MKWare_CopyDataModule_4String
This function block can copy 4 string values. The copy/reset signal should come from the “normal” or “simple” PDA FBs.
VAR_INPUT
VAR_INPUT
CopyData: BOOL; (* Start signal to copy data *)
ResetData: BOOL; (* Start signal to reset data *)
Read_String1: STRING[40];
Read_String2: STRING[40];
Read_String3: STRING[40];
Read_String4: STRING[40];
END_VAR
VAR_OUTPUT
VAR_OUTPUT
Copied_String1: STRING[40];
Copied_String2: STRING[40];
Copied_String3: STRING[40];
Copied_String4: STRING[40];
END_VAR